Home | Site Map | Facilities | User Guide | Schedule | Forms | Research | News | Staff | Links

MACROMOLECULAR CRYSTALLOGRAPHY BEAM TIME REQUEST FORM


Spokesperson: Proposal No:  
Institution:
E-mail Address:
Work Phone:
Citizenship:

Are you interested in establishing a collaboration with a member of the SSRL staff? Yes   No 

      (check any that apply)
unusual experimental setup/technique
inexperience with requested technique
other
     
Are you planning to use SSRL's automated screening/data collection system?
 
Yes   No 

 

Do you want to collect data remotely?
(see User Guide for more information on remote experiments)

 

Yes   No

 If yes, please provide a point person and cell phone number:

If yes to either of the above, do you have a cassette kit?
 
Yes   No
Are you planning to bring UniPuck(s)? Yes   No
Do you have a SSRL unix user account? Yes   No
   If yes, what is your account name?
 
Beam Line Configurations
Beam Line 1-5 7-1 9-1 9-2 11-1 11-3
Flux @90 mA (p/s) 1.7x1010 2.2x1011 4.1x1010 2.5x1011 3.5x1011 2.6x1010
Experiment MAD MONO MAD MAD MAD MONO
Wavelength (Å)
Energy Range (keV)
0.85-2.06
6.0-14.5
0.98
12.67
0.87-0.98
12.6-15.7
0.85-2.06
6.0-14.5
0.82-1.17
10.6-15.2
0.97
12.7
Beam Size (µm) 100-200 50-200 50-250 50-200 100-250 50-250
Detector Q315R Q315R Q315R MAR325 MAR325 Q4
Detector Size (mm2) 315x315 315x315 315x315 325x325 325x325 188x188
Xtal-detector (mm) 90-540 110-650 95-650 95-650 90-650 110-650
Throughput (images/minute) 20 20 20 13 13 5
Phone (+1-650) 926-5215 926-5271 926-5291 926-5292 926-8648 926-8656
 
Common Facilities
Beamline Hardware Stanford Automated Mounting System (SAM) Xe/Kr Incubation Toolboard Other Tools
Computing Resources Control Software Blu-Ice   Web-Ice Computers Software Data Backup

 

* Wavelengths between 0.8 and 0.6 are available only if requested in advance, please use Other Scheduling Comments field provided below.
Experiment(s): Beam Line Choices: No. of  8-hr shifts  requested per trip:
MAD / SAD      1st Choice: 2nd Choice: Max
Min
Element(s):  
Energies:     
Monochromatic 1st Choice: 2nd Choice: Max
Min
Ultra High Resolution
(< 1.0 Å)
1st Choice: 2nd Choice: Max
Min

 

How would you prefer shifts to be scheduled?
Contiguously
Concurrently on two beam lines
Split
 
List desirable dates:   
List dates when you CANNOT accept beam time:   
Other scheduling comments:   
 

List ALL Collaborators Participating in Experiment
Note: Citizenship and radiation training/GERT information is not required if previously provided to us.

Name

Email Address

 Status
(check applicable )

Country of Citizenship
(for onsite users)

1:  Onsite Remote Access  
2: 

Onsite Remote Access

3: 

Onsite Remote Access

4: 

Onsite Remote Access

5: 

Onsite Remote Access

6: 

Onsite Remote Access

7: 

Onsite Remote Access

8: 

Onsite Remote Access

9: 

Onsite Remote Access

10: 

Onsite Remote Access

 

SMB Sample Preparation Lab Equipment Required:
Ultracentrifuge EPR Spectrophotometer Wetlab Bench Space
Glove Box Glove Bag Fume Hood Cold Room
Auxillary Crystallographic Equipment Required:
Variable Temp. Cryostat Xe/Kr
      (flash freeze)
Xe/Kr Cell (RT)  
MSC Cryo-Xe/Kr-Siter Kappa Geometry


Other Equipment:
            





   Check this box if shipping a liquid nitrogen dewar.  Using the Shipping Dewars to SSRL form is always highly encouraged for shipments, but is now a requirement for remote access experiments.

Safety Concerns:
YES
NO
Are you bringing heavy atom solutions or any other hazardous substances to SSRL? (A hazardous material includes anything ignitable, corrosive, toxic-including carcinogens, reactive-including gases, and radioactive)
If yes, list all substances and quantities and please indicate whether the crystals are soaked or are in stock solution.
YES
NO
Are you bringing Biohazards to SSRL? (infectious/pathogenic agents; viruses, toxin producing agents, r-DNA, etc.) If yes, list biohazards, quantities and NIH classifications: (ONLY CLASS 1 & 2 BIOHAZARDS MAY BE BROUGHT TO SSRL)
YES
NO
Are you bringing hazardous equipment to SSRL (e.g. lasers, high voltage, high pressure, cryogenic apparatus, etc.)?
If yes, please list:
  If answered yes to any of the above, please complete a hazard form.
 
YES
NO
NA
Have you made provisions to earthquake brace your equipment (against 0.75G lateral acceleration) while at SSRL?
YES
NO
Will human subjects or laboratory animals be used in this experiment?
If yes, please contact SSRL Safety Officer, Matthew Padilla, 650-926-3861
NO Changes   Please state ALL CHANGES to original proposal (if any) to avoid on-line delays. (Samples, safety issues, use of propane and/or ethane gas, etc.)